BMM FC EC 15mL - Bottom Magnetic Mount Front Contact Electrochemical Cell, 15mL

[powr-form-builder id=eb1c42d8_1505226564]

  • €1,449.00

SKU: C-A-BMM_FC_EC-15-5x5

Order today, and we'll ship your package between and .


This is a static voltammetry cell with variants for different sample dimensions. The sample is loaded from the bottom via magnetic mount, while counter or/and reference electrodes are mounted in the lid as either 2-, or 3-electrode configuration. The cell is constructed with materials that are inert to the sample environment (glass and PEEK), and it can be used with FKM/EPDM O-rings or FFKM O-rings for aqueous or organic electrolyte requirements respectively. The construction is gas-tight and inert gas can be bubbled through the electrolyte to remove and exclude contaminants such as air or water. 
The cell is also available as a screw mount variant for applications where a magnetic assembly is not preferred.

Application note
The reference electrode tip should be placed close to the sample surface to ensure a negligible potential drop throughout the electrolyte solution during low-current experiments. The strength with which the magnets hold the sample is adjusted by adding or removing the washers under the magnets. Thanks to this procedure, the distance between the magnets changes, and with it the force of their attraction.
Various auxiliary electrodes are suitable for this cell including metal wire and metal plate electrodes as well as carbon-based electrodes (graphite or Glassy Carbon). If a purge gas is used, stop the flow during experiments for better results. For troubleshooting instruction see the redox.me blog post.

Specification
nominal exposure area: 0.07 cm2 for 5x5mm20.2 cm2 for 7x7mm2, 0.5 cm2 for 10x10mm2, and 1.33 cm2 for 15x15mm2
minimum electrolyte volume: 2.5 mL
maximum electrolyte volume: 15 mL
electrode plug diameter: 6 mm
substrate size: 5x5mm2, 7x7mm2, 10x10mm2, and 15x15mm2, other sizes available on request
minimum substrate thickness: 0.4 mm*

*lower thicknesses are also feasible when using a pad below the sample

Intrastat data
HS Code: 90309000
Country of Origin: Sweden
NET weight: 100g

Product includes
1 x lid – 0001CPEMA
1 x glass chamber – 0002PGLMA
1 x bottom casing
1 x sample mount
1 x tantalum contact
1 x plug

Related products
Monolayer Graphene on SiC - 15 mm x 15 mm
Glassy Carbon Plates
Metal Plate Electrodes
Noble Metal Plate Electrodes
Boron-Doped Diamond Electrodes
Metal Wire Auxiliary Electrode - 50HX15 0.6/250 mm
Metal Wire Auxiliary Electrode - ST 0.6/custom
Silver Chloride Reference Electrode - 70mm
Non-aqueous Silver/Silver Ion Reference Electrode
Graphite rod electrode - GR 6/70 mm


We Also Recommend